Page 12 - 消防月刊-102年9月號
P. 12
Іዷܓ֛ᄃʘᏐ͜
AutoÑIgnition Temperature Testing Apparatus
Application
ྡā˖cʫ݁ऊԣ ю᎑ন
˦Ө೯͛ܝd੶ϾϞɢʘ༦ᗇৰ̙пৎ˦ࡡΪк֛ʱ̮ؓdһ̙ʺ˦ӨࡡΪሜ
ݟᛠ֛ࣣʘᗇኽɢdʹʝ༌ਪࣛ͵Ϊ༦ᗇᆽϾˡცεԊiν˸ዷ૰ᐽ˦ࣩࣛમණ
ʘ༦ᗇʕᏨ̈ዷ૰dཥኜண௪˦Өۆண௪ʫঐ೯ତஷཥdЇฆʃ˦๕ۆ̙͟
ಞπ༦ᗇʿɛٙБމΪ९ਂމРᗇi್˦ӨࡡΪкމІዷΪ९ࣛdۆ̙ீཀႎණਖ਼
ุࣣᘬe˖ᘠeਖ਼ሞᗇޟЇΎତྼ᜕ਂމ˦ӨࡡΪкʘਞϽf
After a fire accidentdpowerful trace evidence could help judge the cause
of fire, strengthen weight of the evidence in the fire cause investigation and
appraisal paper and cut the time of crossÑexamination in the court For example,
inflammable liquid could be found as trace evidence in an arson triggered by
inflammable liquid; power trace could be found as trace evidence in an electrical
appliance fire and small-scale fire could be evidenced through trace evidence or
human behaviors. However, if the auto-ignition was judged as fire cause, we had
to collect professional books, papers, expert argumentation and even provide
experiment results as reference for the judgment.
൩eІዷତj
ίӚϞ̮Ըᆠ๕Ъٙ͜ઋرɨd͟Չ͉Ԓʫ
يሯՑ༺Іዷܓࣛdପ͛ІҢዷደʘ ٙ͛يeيଣאʷኪˀᏐཀdνःʷe
ତdу݊ІዷfϾݔيሯաᆠ೯͛Іዷࣛ ʱ༆eၳΥeіڝe೯ഃЪ͜ପ͛׳ᆠତ
ٙ௰Эܓఱ݊༈يሯٙІዷᓃdɦ၈І d˲ᙑ׳̈ʘᆠঐԴӻ୕ʫᆠ̻ፅяତ
ዷܓiϾίІዷܓࣛd༈̙ዷيሯၾ٤ ႅᆠɽᆠࣛdۆڮԴˀᏐӻ୕ʫܓ
ंટᙃdʔცࠅ˦ఱঐ೯͛ዷደʘତf ɪʺd༺ՑІዷܓࣛуකዷደi̤ɓ၇
ІዷʱމՇ၇ઋرd௰੬Ԉɓ၇ڷϞԬيሯ ً࿒ۆ̮݊͟Ըᆠ๕ٙЪ͜Ͼ೯͛ٙІዷ
10 Fire Safety Monthly